Filters
Question type

Study Flashcards

Nonmetallic sheathed cable is permitted to be installed in a raceway.

A) True
B) False

Correct Answer

verifed

verified

____________________ is the amount that must be subtracted from a desired stub-up height so the bend will come out right.

Correct Answer

verifed

verified

Any installation of liquidtight flexible metal conduit over ____________________ feet in length requires the installation of an equipment grounding conductor.

Correct Answer

verifed

verified

The most common conduit bend is a 90-degree bend also known as a(n) ____________________.

Correct Answer

verifed

verified

stub-up
st...

View Answer

Explain the difference between Type FMC and Type AC or Type MC cable.

Correct Answer

verifed

verified

Conductors must be i...

View Answer

The __________ on a typical conduit hand bender head is where you will place the middle bending mark when doing a three-point saddle bend.


A) arrow
B) rim notch
C) star point
D) hook

E) A) and C)
F) A) and B)

Correct Answer

verifed

verified

Electricians often refer to Type RMC as "heavy wall" conduit.

A) True
B) False

Correct Answer

verifed

verified

A(n) __________ plastic cap on the ends of rigid metal conduit designates inch trade sizes.


A) black
B) red
C) blue
D) None of the above

E) A) and B)
F) B) and D)

Correct Answer

verifed

verified

Electrical metallic tubing (Type EMT) must be secured within 30 inches of every outlet box, junction box, cabinet, and conduit body.

A) True
B) False

Correct Answer

verifed

verified

The __________ on a typical conduit hand bender head is where you will place the bending mark when doing a stub-up bend.


A) arrow
B) rim notch
C) star point
D) hook

E) A) and C)
F) B) and C)

Correct Answer

verifed

verified

__________ is the amount that must be subtracted from a desired stub-up height so the bend will come out right.


A) Sweep
B) Stub height
C) Saddle mark
D) Take-up

E) A) and B)
F) A) and C)

Correct Answer

verifed

verified

Type EMT must be supported at least every __________ along the run.(General Rule)


A) 3 feet
B) 5 feet
C) 10 feet
D) 12 feet

E) B) and C)
F) A) and D)

Correct Answer

verifed

verified

Types RMC, IMC, EMT, and PVC come in standard __________ foot lengths.


A) 5
B) 6
C) 8
D) 10

E) A) and B)
F) A) and C)

Correct Answer

verifed

verified

The __________ on a typical conduit hand bender head is where you will place the bending mark when doing the second 90-degree bend of a back-to-back bend.


A) arrow
B) rim notch
C) star point
D) hook

E) A) and D)
F) A) and B)

Correct Answer

verifed

verified

A(n) __________ bend is a conduit bend that results in a conduit going over an object that is blocking the path of the run.


A) back-to-back
B) field
C) offset
D) saddle

E) A) and B)
F) C) and D)

Correct Answer

verifed

verified

Rigid metal conduit must be supported within __________ of outlet boxes, junction boxes, cabinets, and conduit bodies.(General Rule)


A) 8 inches
B) 10 inches
C) 12 inches
D) 36 inches

E) None of the above
F) A) and B)

Correct Answer

verifed

verified

Schedule 80 rigid PVC conduit has a larger inside diameter than Schedule 40 rigid PVC conduit.

A) True
B) False

Correct Answer

verifed

verified

A(n) __________ bend is a conduit bend formed by two 90-degree bends with a straight length of conduit between the two bends.


A) back-to-back
B) field
C) offset
D) saddle

E) A) and C)
F) A) and B)

Correct Answer

verifed

verified

Explain the purpose of using cutting oil when threading conduit.

Correct Answer

verifed

verified

Makes cutting the threads easi...

View Answer

Although they are not commonly used, threadless couplings and connectors can be used with Type RMC.

A) True
B) False

Correct Answer

verifed

verified

Showing 21 - 40 of 47

Related Exams

Show Answer